The base topic, as configured in the web GUI is prepended to all following topics.
Serial will be replaced with the serial number of the respective device.
General topics
Topic
R / W
Description
Value / Unit
dtu/ip
R
IP address of OpenDTU
IP address
dtu/hostname
R
Current hostname of the dtu (as set in web GUI)
dtu/rssi
R
WiFi network quality
db value
dtu/status
R
Indicates whether OpenDTU network is reachable
online / offline
dtu/uptime
R
Time in seconds since startup
seconds
Inverter total topics
Enabled inverter means, that only inverters with "Poll inverter data" enabled are considered.
Topic
R / W
Description
Value / Unit
ac/power
R
Sum of AC active power of all enabled inverters
W
ac/yieldtotal
R
Sum of energy converted to AC since reset watt hours of all enabled inverters
Kilo watt hours (kWh)
ac/yieldday
R
Sum of energy converted to AC per day in watt hours of all enabled inverters
Watt hours (Wh)
ac/is_valid
R
Indicator whether all enabled inverters where reachable
0 or 1
dc/power
R
Sum of DC power of all enabled inverters
Watt (W)
dc/irradiation
R
Produced power of all enabled inverter stripes with defined irradiation settings divided by sum of all enabled inverters irradiation
%
dc/is_valid
R
Indicator whether all enabled inverters where reachable
0 or 1
Inverter specific topics
serial will be replaced with the serial number of the inverter.
Topic
R / W
Description
Value / Unit
[serial]/name
R
Name of the inverter as configured in web GUI
[serial]/device/bootloaderversion
R
Bootloader version of the inverter
[serial]/device/fwbuildversion
R
Firmware version of the inverter
[serial]/device/fwbuilddatetime
R
Build date / time of inverter firmware
[serial]/device/hwpartnumber
R
Hardware part number of the inverter
[serial]/device/hwversion
R
Hardware version of the inverter
[serial]/status/reachable
R
Indicates whether the inverter is reachable
0 or 1
[serial]/status/producing
R
Indicates whether the inverter is producing AC power
0 or 1
[serial]/status/last_update
R
Unix timestamp of last inverter statistics udpate
seconds since JAN 01 1970 (UTC)
AC channel / global specific topics
Topic
R / W
Description
Value / Unit
[serial]/0/current
R
AC current in ampere
Ampere (A)
[serial]/0/efficiency
R
Ratio AC Power over DC Power in percent
%
[serial]/0/frequency
R
AC frequency in hertz
Hertz (Hz)
[serial]/0/power
R
AC active power in watts
Watt (W)
[serial]/0/powerdc
R
DC power in watts
Watt (W)
[serial]/0/powerfactor
R
Power factor in percent
%
[serial]/0/reactivepower
R
AC reactive power in VAr
VAr
[serial]/0/temperature
R
Temperature of inverter in degree celsius
Degree Celsius (°C)
[serial]/0/voltage
R
AC voltage in volt
Volt (V)
[serial]/0/yieldday
R
Energy converted to AC per day in watt hours
Watt hours (Wh)
[serial]/0/yieldtotal
R
Energy converted to AC since reset watt hours
Kilo watt hours (kWh)
DC input channel topics
[1-4] represents the different inputs. The amount depends on the inverter model.
Topic
R / W
Description
Value / Unit
[serial]/[1-4]/current
R
DC current of specific input in ampere
Ampere (A)
[serial]/[1-4]/name
R
Name of the DC input channel as configured in web GUI
[serial]/[1-4]/irradiation
R
Ratio DC Power over set maximum power (in web GUI)
%
[serial]/[1-4]/power
R
DC power of specific input in watt
Watt (W)
[serial]/[1-4]/voltage
R
DC voltage of specific input in volt
Volt (V)
[serial]/[1-4]/yieldday
R
Energy converted to AC per day on specific input
Watt hours (Wh)
[serial]/[1-4]/yieldtotal
R
Energy converted to AC since reset on specific input
Kilo watt hours (kWh)
Inverter limit specific topics
cmd topics are used to set values. Status topics are updated from values set in the inverter.
Topic
R / W
Description
Value / Unit
[serial]/status/limit_relative
R
Current applied production limit of the inverter
% of total possible output
[serial]/status/limit_absolute
R
Current applied production limit of the inverter
Watt (W)
[serial]/cmd/limit_persistent_relative
W
Set the inverter limit as a percentage of total production capability. The value will survive the night without power. The updated value will show up in the web GUI and limit_relative topic immediatly.
%
[serial]/cmd/limit_persistent_absolute
W
Set the inverter limit as a absolute value. The value will survive the night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds.
Watt (W)
[serial]/cmd/limit_nonpersistent_relative
W
Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. The value must be published non-retained, otherwise it will be ignored!
%
[serial]/cmd/limit_nonpersistent_absolute
W
Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. The value must be published non-retained, otherwise it will be ignored!
Watt (W)
[serial]/cmd/power
W
Turn the inverter on (1) or off (0)
0 or 1
[serial]/cmd/restart
W
Restarts the inverters (also resets YieldDay)
1
Victron MPPT topics
General
Topic
R / W
Description
Value / Unit
victron/[serial]/PID
R
Product description
text
victron/[serial]/SER
R
Serial number
text
victron/[serial]/FW
R
Firmware number
int
victron/[serial]/LOAD
R
Load output state
ON / OFF
victron/[serial]/CS
R
State of operation
text e. g. "Bulk"
victron/[serial]/ERR
R
Error code
text e. g. "No error"
victron/[serial]/OR
R
Off reasen
text e. g. "Not off"
victron/[serial]/MPPT
R
Tracker operation mode
text e. g. "MPP Tracker active"
victron/[serial]/HSDS
R
Day sequence number (0...364)
int in days
Battery output
Topic
R / W
Description
Value / Unit
victron/[serial]/V
R
Voltage
Volt (V)
victron/[serial]/I
R
Current
Ampere (A)
Solar input
Topic
R / W
Description
Value / Unit
victron/[serial]/VPV
R
Voltage
Volt (V)
victron/[serial]/PPV
R
Power
Watt (W)
victron/[serial]/H19
R
Yield total (user resettable counter)
Kilo watt hours (kWh)
victron/[serial]/H20
R
Yield today
Kilo watt hours (kWh)
victron/[serial]/H21
R
Maximum power today
Watt (W)
victron/[serial]/H22
R
Yield yesterday
Kilo watt hours (kWh)
victron/[serial]/H23
R
Maximum power yesterday
Watt (W)
Pylontech battery topics
Topic
R / W
Description
Value / Unit
battery/settings/chargeVoltage
R
Voltage
Volt (V)
battery/settings/chargeCurrentLimitation
R
BMS requested max. charge current
Ampere (A)
battery/settings/dischargeCurrentLimitation
R
BMS requested max. discharge current
Ampere (A)
battery/stateOfCharge
R
State of Health
%
battery/stateOfHealth
R
State of Charge
%
battery/dataAge
R
How old the data is
Seconds
battery/voltage
R
Actual voltage
Volt (V)
battery/current
R
Actual current
Ampere (A)
battery/temperature"
R
Actual temperature
°C
battery/alarm/overCurrentDischarge
R
Alarm: High discharge current
0 / 1
battery/alarm/underTemperature
R
Alarm: Low temperature
0 / 1
battery/alarm/overTemperature
R
Alarm: High temperature
0 / 1
battery/alarm/underVoltage
R
Alarm: Low voltage
0 / 1
battery/alarm/overVoltage
R
Alarm: High voltage
0 / 1
battery/alarm/bmsInternal
R
Alarm: BMS internal
0 / 1
battery/alarm/overCurrentCharge
R
battery/warning/highCurrentDischarge
R
Warning: High discharge current
0 / 1
battery/warning/lowTemperature
R
Warning: Low temperature
0 / 1
battery/warning/highTemperature
R
Warning: High temperature
0 / 1
battery/warning/lowVoltage
R
Warning: Low voltage
0 / 1
battery/warning/highVoltage
R
Warning: High voltage
0 / 1
battery/warning/bmsInternal
R
Warning: BMS internal
0 / 1
battery/manufacturer
R
Manufacturer
String
battery/charging/chargeEnabled
R
Charge enabled flag
0 / 1
battery/charging/dischargeEnabled
R
Discharge enabled flag
0 / 1
battery/charging/chargeImmediately
R
Charge immediately flag
0 / 1
Huawei AC charger topics
Topic
R / W
Description
Value / Unit
huawei/cmd/limit_online_voltage
W
Online voltage (i.e. CAN bus connected)
Volt (V)
huawei/cmd/limit_online_current
W
Online current (i.e. CAN bus connected)
Ampere (A)
huawei/cmd/limit_offline_voltage
W
Offline voltage (i.e. CAN bus not connected)
Volt (V)
huawei/cmd/limit_offline_current
W
Offline current (i.e. CAN bus not connected)
Ampere (A)
huawei/cmd/mode
W
Controls GPIO output pin to switch slot detect
0 (off) / 1 (on) / 2 (set automatically depending on online_current value) / 3 (set automatically based on Power Meter reading )
huawei/data_age
R
How old the data is
Seconds
huawei/input_voltage
R
Input voltage
Volt (V)
huawei/input_current
R
Input current
Ampere (A)
huawei/input_power
R
Input power
Watt (W)
huawei/output_voltage
R
Output voltage
Volt (V)
huawei/output_current
R
Output current
Ampere (A)
huawei/max_output_current
R
Maximum output current (set using the online limit)
Ampere (A)
huawei/output_power
R
Output power
Watt (W)
huawei/input_temp
R
Input air temperature
°C
huawei/output_temp
R
Output air temperature
°C
huawei/efficiency
R
Efficiency
Percentage
Power Limiter topics
Topic
R / W
Description
Value
powerlimiter/cmd/mode
W
Power Limiter operation mode
see below
powerlimiter/status/mode
R
Get Power Limiter operation mode
see below
Setting any of these modes through MQTT has no effect if the Power Limiter is
disabled by configuration in the web application. The Power Limiter will stay
off in that case.
Three modes are implemented:
0 - Normal operation: The Power Limiter works as configured through the
web application.
1 - Fully disable: The inverter is shut down and the Power Limiter stops
operating, as if it was disabled in the web application.
2 - Unconditional Solar Passthrough: The power limit is set such that all
solar power (adjusted for efficiency) is fed into the home. This is done
irrespective of grid consumption and without consuming energy from the
battery, which is the key difference to the regular Power Limiter Solar
Passthrouh feature. Essentially, the inverter mimics the behavior of a
traditional, non-smart inverter. This can be particularly useful in scenarios
where solar power is better stored elsewhere, such as in an electric car.