Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Linky G1 pilote ne remonte pas la puissance instentannée. #42

Closed
jipem01 opened this issue Oct 28, 2024 · 2 comments
Closed

Linky G1 pilote ne remonte pas la puissance instentannée. #42

jipem01 opened this issue Oct 28, 2024 · 2 comments

Comments

@jipem01
Copy link
Contributor

jipem01 commented Oct 28, 2024

Sur un compteur Linky phase pilote (ADS type 67), les entités suivantes sont indisponibles :

  • Puissance app. instantanée soutirée,
  • Puissance app. max. soutirée n
  • Puissance app. max. soutirée n-1
@jipem01
Copy link
Contributor Author

jipem01 commented Oct 29, 2024

Proposed fix in PR #44

@hekmon
Copy link
Owner

hekmon commented Nov 14, 2024

Mergé ! upcoming 3.0.0-beta4

@hekmon hekmon closed this as completed Nov 14, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants