SetGeneratorToLocalRegulation: set same targetV on all locally regulating generators #3287
Open
quinarygio
wants to merge
5
commits into
main
Choose a base branch
from
generator_local_regulation_consistency
base: main
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Conversation
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
…ating generators Signed-off-by: Giovanni Ferrari <[email protected]>
olperr1
changed the title
SetGeneratorToLocalRegulation : set same targetV on all locally regul…
SetGeneratorToLocalRegulation: set same targetV on all locally regulating generators
Jan 23, 2025
olperr1
requested changes
Jan 23, 2025
@@ -66,19 +66,31 @@ private void setLocalRegulation(Generator generator, ReportNode reportNode) { | |||
|
|||
// Change the regulation (local instead of remote) | |||
generator.setRegulatingTerminal(generator.getTerminal()); | |||
generator.setTargetV(localTargetV); | |||
|
|||
com.powsybl.iidm.network.Bus bus = generator.getTerminal().getVoltageLevel().getBusView().getBus("VL20_0"); |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Don't forget to change the bus detection here.
Signed-off-by: Giovanni Ferrari <[email protected]>
…ue to VL nominal voltage among the regulating terminals Signed-off-by: Giovanni Ferrari <[email protected]>
Signed-off-by: Giovanni Ferrari <[email protected]>
Quality Gate passedIssues Measures |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Please check if the PR fulfills these requirements
Does this PR already have an issue describing the problem?
Fixes #3231
What kind of change does this PR introduce?
What is the current behavior?
What is the new behavior (if this is a feature change)?
Does this PR introduce a breaking change or deprecate an API?
If yes, please check if the following requirements are fulfilled
What changes might users need to make in their application due to this PR? (migration steps)
Other information: