Card Attribute | Modbus Register | Unit | Sunsynk | Solarman |
---|---|---|---|---|
pv1_power_186 | 186 | 1W | PV1 input power | PV1 Power |
pv2_power_187 | 187 | 1W | PV2 input power | PV2 Power |
pv3_power_188 | 188 | 1W | PV3 input power | |
pv4_power_189 | 189 | 1W | PV4 input power | |
pv1_v_109 | 109 | 0.1V | DC voltage 1 | PV1 Voltage |
pv2_v_111 | 111 | 0.1V | DC voltage 2 | PV2 Voltage |
pv3_v_113 | 113 | 0.1V | DC voltage 3 | |
pv4_v_115 | 115 | 0.1V | DC voltage 4 | |
pv1_i_110 | 110 | 0.1A | DC current 1 | PV1 Current |
pv2_i_112 | 112 | 0.1A | DC current 2 | PV2 Current |
pv3_i_114 | 114 | 0.1A | DC current 3 | |
pv4_i_116 | 116 | 0.1A | DC current 4 | |
solarday_108 | 108 | 0.1kWh | Day PV PowerWh | Daily Production |
Card Attribute | Modbus Register | Unit | Sunsynk | Solarman |
---|---|---|---|---|
batchargeday_70 | 70 | 0.1kWh | Day_Batt_Charge _PowerWh | |
batdischargeday_71 | 71 | 0.1kWh | Day_Batt_Discharge_PowerWh | |
battery_out_190 | 190 | 1W | Battery output power | Battery Power |
battery_voltage_183 | 183 | 0.01V | Battery voltage | Battery Voltage |
battery_soc_184 | 184 | 1% | Battery capacity | Battery SOC |
Card Attribute | Modbus Register | Unit | Sunsynk | Solarman |
---|---|---|---|---|
inverter_load_grid_169 | 169 | 1W | L1L2 Total power of grid side L1L2 | Total Grid Power |
grid_buy_day_76 | 76 | 0.1kWh | Day_GridBuy_Power Wh | Daily Energy Bought |
grid_sell_day_77 | 77 | 0.1kWh | Day_GridSell_Power Wh | Daily Energy Sold |
Card Attribute | Modbus Register | Unit | Sunsynk | Solarman |
---|---|---|---|---|
essential_power | 178* | 1W | Load side Total power | Total Load Power |
loadday_84 | 84 | 0.1kWh | SG:Day_Load_Power Wh | Daily Load Consumption |
aux_power_166 | 166 | 1W | GenGen Do micro inverse power input | Micro-inverter Power |
*Calculated through internal card logic if non-essential is used
Card Attribute | Modbus Register | Unit | Sunsynk | Solarman |
---|---|---|---|---|
use_timer_248 | 248 | 0/1 | Time of Use Selling enabled | |
priority_load_243 | 243 | 0/1 | Energy management model | |
inverter_grid_voltage_154 | 154 | 0.1V | L1-N Inverter output voltage L1-N | |
inverter_load_freq_192 | 192 | 0.01Hz L | Load frequency | Load Frequency |
inverter_out_164 | 164 | 0.01A | L1 Inverter output current L1 | Current L1 |
inverter_out_175 | 175 | 1W | Inverter output Total power | Total Power |
grid_status_194 | 194 | 0/1 | Grid side relay status | Grid-connected Status |
inverter_status_59 | 59 | [0-5] | Run state | Running Status |