Aqara corner

Summary

Opple Switches

Introduction

Those switches have 2 modes of operating.

  1. Binded to a dedicated Group of devices, you will be able to command the end device directly. On/Off, Dimmer, and Color Control should be working.

  2. Binded directly with the coordinator, you can get up to 6 events per button.

Domoticz Zigate Plugin behaviours

On the ZigBeeForDomoticZ plugin, we have 3 operating modes:

  1. By default the switch is configured in 6 events per button mode. During the provisioning phase, 1 widget will be created in DomoticZ per button.
  2. You can enable a mode, where the switch will be bound to ZiGate and in that case you will let events. For the 6 butons switch, you will get 3 widgets: 1 On/Off for the 1 row of button, 2 Switch Selector for row two and three.
  3. You can do a bind between the switch and any devices in the ZiGate network. To enable this mode you have a parameter to enable (AqaraOppleBulbMode ) which can be found in the Miscaleneous section.

Technical Findings

  • After reset the switch seems to be broadcasting all actions made on the switch.
  • There is a registration step to be performed if you want to activate Mode 1, and in that case all events will reach the ZiGate and the host via Cluster 0x0012
  • In Mode 2, there is a need to firmware update in order to receive the 0x0300 Color Control cluster. If you have a firmware below or equal to 3.1c, the row 3 of the 6 button switch will not operate.

Lumi Presence Detector FP1 RTCZCGQ11LM

This sensor isn't a Motion Sensor, this is a presence sensor with ability to check if there is some one in or not even if there micro mouvement.

4 parameters for this device

  1. You have to set "resetMotiondelay': 0", parameter otherwise no motion is detected until a real physical leave
  2. Other Parameter
  • RTCZCGQ11LMMotionSensibility = Motion sensibility for Presence Detector FP1 RTCZCGQ11LM : 1=low 2=mid 3=high
  • RTCZCGQ11LMApproachDistance = Approach Distance for Presence Detector FP1 RTCZCGQ11LM : 0=far 1=mid 2=close
  • RTCZCGQ11LMMonitoringMode = Monitoring mode for Presence Detector FP1 RTCZCGQ11LM 1 : 0=undirected 1=left/right ability to check left/right enter/leaving