This update is mainly about end-device handling for both battery powered (sleeping) and mains powered (rxOnWhenIdle = true) devices.

  • New firmware 0x26240500
  • Support up to 32 directly connected end-devices (formerly 10)
  • Fix mains powered end-devices become unresponsive
  • Support mac data request polling for end-devices which are connected directly to the gateway
  • New ZCL time cluster implementation #774
  • Fix group.state any_on and all_on
  • Support Trust motion sensor (ZPIR-8000) and remote (ZYCT-202) in REST-API
  • Fix memory corruption bugs
  • Improve setup of Philips Hue dimmer switch
  • Support manufacturer specific ZCL attributes in ZCLDB fb90032
  • Fix view update issues in Phoscon App
  • Fix gateway firmware version number not shown in Phoscon App, however there is still a bug that after an update the update button might not disappear.