Model resolution based deconvolution (SALSA) improves frequency domain photo acoustic reconstruction. The full paper with detailed explanation and formulation can be found in https://doi.org/10.1121/10.0013829
Input the parameters in Paramters section. Range of frequencies selected - (100kHz - 2.5Mhz) for FUNDUS and Derenzo Phantom and (5kHz - 150kHz) for Breast phantom. Set the required SNR and FOV. For split/ discontinuous frequency ranges, set fh_end, fh_start, wnh parameters.
Calculate Weight matrix (forward modelling) using function Calculate_W_matrix.m function. Regularization paramter for Derenzo phantom and FUNDUS is 100 and 2e11 for Breast phantom.
Calculte P = WX to get pressure matrix (Complete forward model).
Reconstruction is performed with a penalty function multiplied to regularization paramter.
Set the same paramters as in step 1. All the deconvolutions were based on SALSA approach and were done for 100 iterations for each of the penalized reconstructions.