16 changes: 16 additions & 0 deletions docs/changes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -90,6 +90,22 @@ will also work with the prior version of the file (but not vice versa).
* Added support for environment variables 'TESTCASES' for specifying testcases
for the unit test, and 'TESTOPTS' for specifying pytest options. (issue #461)

* Added support for the new partition power consumption metrics in z16
(issue #448):

In metric group 'zcpc-environmentals-and-power':

- 'zhmc_cpc_total_partition_power_watt' - Total power consumption of all
partitions of the CPC
- 'zhmc_cpc_total_infrastructure_power_watt' - Total power consumption of all
infrastructure components of the CPC
- 'zhmc_cpc_total_unassigned_power_watt' - Total power consumption of all
unassigned components of the CPC

In metric group 'logical-partition-usage':

- 'zhmc_partition_power_watt' - Power consumption of the partition

**Cleanup:**

* Increased versions of GitHub Actions plugins to increase node.js runtime
Expand Down
4 changes: 4 additions & 0 deletions docs/usage.rst
Original file line number Diff line number Diff line change
Expand Up @@ -482,6 +482,9 @@ zhmc_cpc_heat_load_total_btu_per_hour C+D G Total heat l
zhmc_cpc_heat_load_forced_air_btu_per_hour C+D G Heat load of the CPC covered by forced-air
zhmc_cpc_heat_load_water_btu_per_hour C+D G Heat load of the CPC covered by water
zhmc_cpc_exhaust_temperature_celsius C+D G Exhaust temperature of the CPC
zhmc_cpc_total_partition_power_watt C G Total power consumption of all partitions; only with SE feature environmental-metrics
zhmc_cpc_total_infrastructure_power_watt C+D G Total power consumption of all infrastructure comp.; only with SE feature environmental-metrics
zhmc_cpc_total_unassigned_power_watt C+D G Total power consumption of all unassigned comp.; only with SE feature environmental-metrics
zhmc_cpc_power_cord1_phase_a_watt C+D G Power in Phase A of line cord 1 - 0 if not available
zhmc_cpc_power_cord1_phase_b_watt C+D G Power in Phase B of line cord 1 - 0 if not available
zhmc_cpc_power_cord1_phase_c_watt C+D G Power in Phase C of line cord 1 - 0 if not available
Expand Down Expand Up @@ -524,6 +527,7 @@ zhmc_partition_crypto_adapter_usage_ratio D G Usage ratio
zhmc_partition_network_adapter_usage_ratio D G Usage ratio of all network adapters of the partition
zhmc_partition_storage_adapter_usage_ratio D G Usage ratio of all storage adapters of the partition
zhmc_partition_zvm_paging_rate_pages_per_second C G z/VM paging rate in pages/sec
zhmc_partition_power_watt C G Power consumption of the partition; only with SE feature environmental-metrics
zhmc_partition_processor_mode_int C+D G Allocation mode for processors as an integer (0=shared, 1=dedicated); since HMC 2.15
zhmc_partition_threads_per_processor_ratio D G Number of threads per processor used by OS
zhmc_partition_defined_capacity_msu_per_hour C G Defined capacity expressed in terms of MSU per hour
Expand Down
20 changes: 20 additions & 0 deletions examples/metrics.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -337,6 +337,11 @@ metrics:
percent: false
exporter_name: zvm_paging_rate_pages_per_second
exporter_desc: z/VM paging rate in pages/sec
power-consumption:
if: "'environmental-metrics' in se_features"
percent: false
exporter_name: power_watt
exporter_desc: Power consumption of the partition

channel-usage:
channel-usage:
Expand Down Expand Up @@ -1140,6 +1145,21 @@ metrics:
percent: false
exporter_name: exhaust_temperature_celsius
exporter_desc: Exhaust temperature of the CPC
total-partition-power-consumption-watts:
if: "'environmental-metrics' in se_features" # and only in classic mode (no need to put that into condition)
percent: false
exporter_name: total_partition_power_watt
exporter_desc: Total power consumption of all partitions of the CPC (CPU, memory, I/O adapters)
total-infrastructure-power-consumption-watts:
if: "'environmental-metrics' in se_features"
percent: false
exporter_name: total_infrastructure_power_watt
exporter_desc: Total power consumption of all infrastructure components of the CPC (TOR switches, SE/HMAs, PDUs)
total-unassigned-power-consumption-watts:
if: "'environmental-metrics' in se_features"
percent: false
exporter_name: total_unassigned_power_watt
exporter_desc: Total power consumption of all unassigned components of the CPC (CPU, memory, I/O adapters)

environmental-power-status:
linecord-one-power-phase-A: